How to Install a Legrand radiant® Tamper-Resistant Outlet: Step-by-Step Guide
By Legrand US | Delivering and Managing Power, Light, and Data | Published: 2026-07-28
Category: How-to Guides
Learn how to install a Legrand radiant® tamper-resistant outlet with this step-by-step DIY guide. Includes wiring tips, safety precautions, and tool recommendations.
Upgrading your home's electrical outlets to tamper-resistant models is one of the smartest safety improvements you can make. Legrand's radiant® collection combines modern aesthetics with advanced protection, including SafeLock® technology that blocks foreign objects from entering the slots. Whether you're replacing an old receptacle or wiring a new one, this guide will walk you through the installation process step by step.
Before you begin, always turn off the power to the circuit at the breaker panel and verify it's off with a voltage tester. If you're unsure about any step, consult a licensed electrician. With the right tools and careful attention, you can complete this project in about 30 minutes per outlet.
Tools and Materials You'll Need
Before starting, gather the following: a voltage tester, wire strippers, a screwdriver (flathead and Phillips), needle-nose pliers, and a flashlight. You'll also need the new Legrand radiant® tamper-resistant receptacle, a compatible wall plate (such as the radiant® 1-Gang Screwless Wall Plate, Graphite for a sleek finish), and wire nuts if not included.

For older homes, you may also need a box extender or a new electrical box if the existing one is damaged. Always use a receptacle rated for your circuit's amperage—15A for standard residential circuits, 20A for heavy-duty applications.
- Safety tip: Wear insulated gloves and use a non-contact voltage tester to confirm power is off.
Step 1: Remove the Old Outlet
Start by removing the wall plate and unscrewing the old receptacle from the electrical box. Carefully pull the receptacle out, noting how the wires are connected. You'll typically see three wires: black (hot), white (neutral), and bare copper (ground). In some configurations, you may also have a red wire for a split-circuit outlet.
Loosen the terminal screws and disconnect each wire. If the wires are connected via push-in terminals on the back, press the release slot with a small screwdriver to free them. Inspect the wires for damage; if they are frayed or brittle, trim them back to fresh copper using wire strippers.
Step 2: Prepare the New radiant® Outlet
Take your new Legrand radiant® tamper-resistant receptacle and strip about 3/4 inch of insulation from each wire end if needed. The radiant® outlet features color-coded terminal screws: brass for hot (black), silver for neutral (white), and green for ground (bare copper). Loop each wire clockwise around its respective screw and tighten securely.
For added convenience, the radiant® outlet also accepts back-wiring via the clamp terminals. Insert the stripped wire into the appropriate hole and tighten the screw to clamp it in place. This method is faster and often provides a more secure connection.
- Tip: Use the loop method for stranded wire and the clamp method for solid wire to ensure a tight connection.
Step 3: Connect the Wires
Connect the black (hot) wire to the brass screw on the side of the outlet. Connect the white (neutral) wire to the silver screw. Connect the bare copper (ground) wire to the green screw. If your box has a ground wire, use a green wire nut to join it to the outlet's ground pigtail if provided.
Double-check that no bare wire is exposed beyond the screw terminals and that the wire insulation is flush with the terminal. Gently push the wires back into the box, ensuring they are folded neatly and not pinched.
Step 4: Secure the Outlet and Attach the Wall Plate
Align the outlet with the mounting screws in the electrical box and tighten them evenly. The radiant® outlet's slim profile ensures it sits flush against the wall. Once the outlet is secure, attach the wall plate. For a modern look, consider the radiant® 1-Gang Screwless Wall Plate, Graphite, which snaps on without visible screws.
Turn the power back on at the breaker and test the outlet using a plug-in tester or a simple lamp. The tamper-resistant mechanism should allow a two-prong plug to insert evenly but resist a single object. If the outlet doesn't work, turn off the power and recheck your connections.
- Safety check: Always test with a GFCI tester if the outlet is in a wet location like a kitchen or bathroom.
Troubleshooting Common Issues
If the outlet doesn't sit flush, check that the wires are pushed fully into the box and not bulging behind the receptacle. If the wall plate doesn't fit, you may need a different size or a box extender. For persistent problems, consult the manufacturer's instructions or call a professional.
Legrand's radiant® tamper-resistant outlets are designed for easy installation, but if you encounter a situation where the existing box is too shallow, consider using a 9-inch Dual-Purpose In-Wall Enclosure for more space. This enclosure accommodates deeper devices and simplifies wiring.

- Remember: Tamper-resistant outlets are required by code in new construction and renovations for all 15A and 20A receptacles in residential areas.
Installing a Legrand radiant® tamper-resistant outlet is a straightforward DIY project that enhances safety and modernizes your home. With the right tools and careful attention to wiring, you can complete the job confidently. For a complete upgrade, pair your new outlet with a matching wall plate from the radiant® collection. Explore the radiant® Tamper-Resistant 15A Simplex Self-Test GFCI Receptacles with SafeLock® Protection for added safety in kitchens and bathrooms.